Description
"B" terminal circuit supplies power to charge the battery and operate the vehicle's electrical system.
Diagnosis Procedure
1.CHECK "B" TERMINAL CONNECTION
2.CHECK "B" TERMINAL CIRCUIT
Check voltage between generator connector F6 terminal 1 and ground.

1 - ground Battery voltage
3.CHECK "B" TERMINAL CONNECTION (VOLTAGE DROP TEST)

1 - B+ Less than 0.2V
Power generation voltage variable control system operation
inspection
L terminal circuit (open)Basic inspection
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow (With EXP-800 NI or GR8-1200 NI)
CHARGING SYSTEM DIAGNOSIS WITH EXP-800 NI OR GR8-1200 NI
To test the charging system, use the following special service tools:
EXP-800 NI Battery and electrical diagnostic analyzer
GR8-1200 NI Multitasking battery and ...
Preparation
Special Service Tools
The actual shapes of Kent-Moore tools may differ from those of special
service tools illustrated here.
Commercial Service Tools
...
P0444, P0445 evap canister purge volume control solenoid
valve
Description
The EVAP canister purge volume control solenoid valve is used to
control the flow rate of fuel vapor from the EVAP canister. The EVAP
canister purge volume control solenoid valve is moved by ON/OFF
pulses from the ECM. The longer the ON pulse, the greater the
amount of fuel ...