NOISE, VIBRATION AND HARSHNESS (NVH) TROUBLESHOOTING
NVH Troubleshooting Chart
Use chart below to help you find the cause of the symptom. If necessary, repair or replace these parts.

×: Applicable
Wiring diagram
PrecautionPower supply and ground circuit
Diagnosis Procedure
1. CHECK FUSE AND FUSIBLE LINK
Check if the following BCM fuses or fusible link are blown
2. CHECK POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect BCM.
Check voltage between BCM harness connector and ground.
3. CHECK GROUND CIRCUIT
Check continuit ...
P1709 incompleted data writing
Description
When TCM does not store calibration data (individual
characteristic value) of each solenoid valve that is
stored in the ROM assembly (in the control valve), a malfunction is detected.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
NOTE:
Immediately after performing ...
Trunk open function symptoms
TRUNK LID OPENER SWITCH
TRUNK LID OPENER SWITCH : Symptom Table
TRUNK OPEN FUNCTION MALFUNCTION
NOTE:
Before performing the diagnosis in the following table, check
"WORK FLOW". Refer to DLK-9, "Work Flow".
Check that vehicle is under the condition shown in "Conditions
of ve ...