Unit removal and installation
Seat belt systemInterior room lamp control circuit
Description
Controls each interior room lamp (ground side) by PWM signal.
NOTE: PWM signal control period is
approximately 250 Hz (in the gradual brightening/dimming).
Component Function Check
CAUTION: Before performing the diagnosis,
check that the following is normal.
Battery saver ou ...
Standardized relay
Description
NORMAL OPEN, NORMAL CLOSED AND MIXED TYPE RELAYS
Relays can mainly be divided into three types: normal open, normal closed and
mixed type relays
TYPE OF STANDARDIZED RELAYS
1M * 1 Make
2M * 2 Make
1T * 1 Transfer
1M*1B * 1 Make 1 Break
...
B2608 starter relay
Description
Located in IPDM E/R, it runs the starter motor. The
starter relay is turned ON by the BCM when the ignition
switch is in START position. IPDM E/R transmits the starter relay ON signal to
BCM via CAN communication.
DTC Logic
DTC DETECTION LOGIC
NOTE: