Description
| Part name | Description |
| AV CONTROL UNIT |
|
DTC Logic

U1010 control unit (CAN)
U1216 AV control unitDiagnosis and repair workflow
Work Flow
OVERALL SEQUENCE
DETAILED FLOW
1. GET INFORMATION FOR SYMPTOM
Get the detailed information from the customer about the symptom (the
condition and the environment when
the incident/malfunction occurred).
2. CHECK DTC
Check DTC.
Perform the following procedure if DTC is di ...
Power supply and ground circuit
Diagnosis Procedure
1. CHECK FUSES AND FUSIBLE LINK
Check that the following IPDM E/R fuses or fusible link are not blown.
2. CHECK POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect IPDM E/R connectors.
Check voltage between IPDM E/R harness connector and ground.
3. CHE ...
Control unit
Removal and Installation
A/C SWITCH ASSEMBLY
Removal
Remove cluster lid D. Refer to IP-10, "Exploded View".
Remove the A/C switch assembly from cluster lid D.
Installation
Installation is in the reverse order of removal.
A/C AUTO AMP.
Removal
Remove the audio unit.
...