Service data and specifications (SDS)
Basic inspectionC1115 ABS sensor [abnormal signal]
Description
When the sensor rotor rotates, the magnetic field changes. It converts the
magnetic field changes to current
signals (rectangular wave) and transmits them to the ABS actuator and electric
unit (control unit).
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.CHECK ...
Variable induction air system
Description
Power Valves 1 and 2
The power valves 1 and 2 are installed in intake manifold collector and used to
control the suction passage of
the variable induction air control system. They are set in the fully closed or
fully opened position by the power
valve actuators 1 and 2 operate ...
Trunk release solenoid
Description
Performs trunk lid open with signal from BCM.
Component Function Check
1. CHECK TRUNK LID OPENER CANCEL SWITCH
Check trunk lid opener cancel switch position.
2. CHECK FUNCTION
Perform Active Test TRUNK/GLASS HATCH with CONSULT.
Touch "OPEN" and check that trunk lid opens
...