"AIR BAG" Warning Lamp Does Not Turn Off
DIAGNOSTIC PROCEDURE
1.CHECK CONDITION OF AIR BAG MODULE
Inspect for any deployed air bag modules or seat belt pre-tensioners.
2.CHECK THE AIR BAG FUSE
Check 10A fuse [No. 2, located in the fuse block (J/B)].
3.CHECK AIR BAG FUSE AGAIN
Replace 10A fuse [No. 2, located in the fuse block (J/B)] and turn ignition switch ON.
4.CHECK AIR BAG DIAGNOSIS SENSOR UNIT
Connect CONSULT.
5.CHECK HARNESS CONNECTION
Check for loose connections between the combination meter and the air bag diagnosis sensor unit.
"AIR BAG" Warning Lamp Does Not Turn On
DIAGNOSTIC PROCEDURE
1.CHECK METER FUSE
Check the 10A fuse [No. 4, located in the fuse block (J/B)].
2.REPLACE METER FUSE AND CHECK AGAIN
Replace 10A fuse [No. 4, located in the fuse block (J/B)] and turn ignition switch ON.
3.CHECK HARNESS CONNECTIONS BETWEEN AIR BAG DIAGNOSIS SENSOR UNIT AND
COMBINATION
METER
Inspect the harness and connectors between the air bag diagnosis sensor unit and the combination meter.
4.CHECK COMBINATION METER
Disconnect the air bag diagnosis sensor unit harness connectors and turn ignition switch ON.
Diagnosis and repair workflow
Work Flow
OVERALL SEQUENCE
DETAILED FLOW
1.CHECK SYMPTOM
Check the malfunction symptoms by performing the following items.
Interview the customer to obtain the malfunction information (conditions
and environment when the malfunction
occurred).
Check the symptom.
2.SELF-DIAGNOS ...
Power supply and ground circuit
Diagnosis Procedure
1.CHECK GROUND CONNECTION-I
Turn ignition switch OFF.
Check ground connection E9. Refer to Ground Inspection
2.CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-I
Disconnect ECM harness connector.
Check the continuity between ECM harness connector and ground.
Also che ...
Illumination
Wiring Diagram
...