Description
The terminal "L" circuit controls the charge warning lamp. The charge warning lamp turns ON when the ignition switch is set to ON or START. When the generator is providing sufficient voltage with the engine running, the charge warning lamp turns off. If the charge warning lamp illuminates with the engine running, a malfunction is indicated.
Diagnosis Procedure
1.CHECK "L" TERMINAL CIRCUIT (SHORT)
2.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)

L terminal circuit (open)
Wiring diagramHeated seat
Wiring Diagram
...
Vehicle load capacity
Do not exceed the load limit of your vehicle
shown as "The combined weight of
occupants and cargo" on the Tire and
Loading Information label. Do not exceed
the number of occupants shown as
"Seating Capacity" on the Tire and Loading
Information label.
To get "the combined weight of occupants ...
Power supply and ground circuit
Diagnosis Procedure
1. CHECK FUSE AND FUSIBLE LINK
Check if the following BCM fuses or fusible link are blown
2. CHECK POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect BCM.
Check voltage between BCM harness connector and ground.
3. CHECK GROUND CIRCUIT
Check continuit ...