Description
The displayed ambient air temperature is higher than the actual temperature.
The displayed ambient air temperature is lower than the actual temperature.
Diagnosis Procedure
1.COMBINATION METER INPUT SIGNAL
Select "METER/M&A" on CONSULT.
Using "OUTSIDE TEMP" on DATA MONITOR, compare the value of DATA MONITOR with the actual ambient temperature. DATA MONITOR value and actual ambient temperature should be close.
Intermittent incident
Inspection Procedure
INTERMITTENT TROUBLE
An intermittent incident may have occured in the past but is not being
detected currently. This DTC will not bedetected on SELF DIAG [CURRENT], but
may be viewed on SELF DIAG [PAST] using CONSULT.
Trouble Diagnosis with CONSULT
DIAGNOSTIC PROCEDURE 4 ...
BCM branch line circuit
Diagnosis Procedure
1.CHECK CONNECTOR
Turn the ignition switch OFF.
Disconnect the battery cable from the negative
terminal.
Check the terminals and connectors of the BCM
for damage, bend and loose connection (unit side and
connector side).
2. ...
RGB (B: blue) signal circuit
Description
Transmit the image displayed with AV control unit with RGB signal to the
display unit.
Diagnosis Procedure
1.CHECK CONTINUITY RGB (B: BLUE) SIGNAL CIRCUIT
Turn ignition switch OFF.
Disconnect display unit connector M141 and AV control unit
connector M117.
Check contin ...