STARTING SYSTEM
System Diagram

System Description
The starter motor plunger closes and provides a closed circuit between the battery and the starter motor. The starter motor is grounded to the cylinder block. With power and ground supplied, the starter motor operates.
Component Description

Basic inspectionHorn function
Description
Perform answer-back for each operation with horn.
Component Function Check
1. CHECK FUNCTION
Select HORN in "ACTIVE TEST" mode with CONSULT.
Check the horn (high/low) operation.
Diagnosis Procedure
1. CHECK HORN FUNCTION
Check horn function with horn switch
2. CHECK ...
C1105, C1106, C1107, C1108 wheel sensor
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.CHECK SELF DIAGNOSTIC RESULT
With CONSULT.
Start engine and drive vehicle at approximately 21 km/h (13 MPH)
or more for approximately 5 minutes.
Perform self diagnostic result
Diagnosis Procedure
CAUTION:
Do not check ...
On board refueling vapor recovery (ORVR)
Description
From the beginning of refueling, the air and vapor inside the fuel tank go
via the refueling EVAP vapor cut
valve and EVAP/ORVR line to the EVAP canister. The vapor is absorbed by the EVAP
canister and the air is
released to the atmosphere.
When the refueling has reached ...