STARTING SYSTEM
System Diagram

System Description
The starter motor plunger closes and provides a closed circuit between the battery and the starter motor. The starter motor is grounded to the cylinder block. With power and ground supplied, the starter motor operates.
Component Description

Basic inspectionB1017 - B1022 occupant classification system
Description
DTC B1017 - B1022 OCCUPANT CLASSIFICATION SYSTEM (OCS)
The occupant classification system control unit is wired to the air bag
diagnosis sensor unit. The air bag diagnosissensor unit will monitor the
occupant classification system for control unit and sensor mat failures and
inter ...
Extending engine run time
The remote start feature can be extended one
time by performing the steps listed in "Remote
starting the vehicle" in this section. Run time will
be calculated as follows:
The first 10 minute run time will start when
the remote start function is performed.
The second 10 minutes will start ...
Power supply and ground circuit
Diagnosis Procedure
1. CHECK FUSE AND FUSIBLE LINK
Check if the following BCM fuses or fusible link are blown
2. CHECK POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect BCM.
Check voltage between BCM harness connector and ground.
3. CHECK GROUND CIRCUIT
Check continuit ...