Diagnosis and repair workflowInsufficient heating
Component Function Check
Symptom
Insufficient heating
No warm air comes out. (Airflow volume is normal.)
INSPECTION FLOW
1. CONFIRM SYMPTOM BY PERFORMING OPERATION CHECK - TEMPERATURE INCREASE
Press the AUTO switch.
Turn temperature control switch (driver side) clockwise until 32C
...
Basic inspection
DIAGNOSIS AND REPAIR WORKFLOW
Trouble Diagnosis Flow Chart
Trouble Diagnosis Procedure
INTERVIEW WITH CUSTOMER
Interview with the customer is important to detect the root cause of CAN
communication system errors and to
understand vehicle condition and symptoms for proper trouble diagnosis ...
SRS air bag system
"AIR BAG" Warning Lamp Does Not Turn Off
DIAGNOSTIC PROCEDURE
1.CHECK CONDITION OF AIR BAG MODULE
Inspect for any deployed air bag modules or seat belt pre-tensioners.
2.CHECK THE AIR BAG FUSE
Check 10A fuse [No. 2, located in the fuse block (J/B)].
3.CHECK AIR BAG FUSE AGAIN
Replace 10A fuse ...