Power window lock switch
Power window main switchYaw rate/side/decel G sensor
Exploded View
Yaw rate/side/decel G sensor
Yaw rate/side/decel G sensor harness
connector
Front
Removal and Installation
CAUTION:
Do not drop or strike the yaw rate/side/decel G sensor to
prevent damage.
Do not use power tool to remove the yaw rate/side/decel G s ...
IPDM-E branch line circuit
Diagnosis Procedure
1.CHECK CONNECTOR
Turn the ignition switch OFF.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the IPDM E/R for damage,
bend and loose connection (unit side
and connector side).
2.CHECK HARNESS FOR OPEN CIRCUIT
...
Basic inspection
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow (With EXP-800 NI or GR8-1200 NI)
CHARGING SYSTEM DIAGNOSIS WITH EXP-800 NI OR GR8-1200 NI
To test the charging system, use the following special service tools:
EXP-800 NI Battery and electrical diagnostic analyzer
GR8-1200 NI Multitasking battery and ...